MTOWER 2CH
CONTROL INSTRUMENT
MTOWER 2CH control instruments are a series of fully feature control systems for cooling towers.
They manage simultaneously two parameters: pH or ORP or chlorine, conductivity or inductive conductivity (to specify on order) and temperature. Probes are not included.
They can be remotely controlled through the exclusive web management system ERMES.
MTOWER 2CH models have: widescreen LCD display, easy control by encoder wheel, current Feed & Bleed display, local & remote control, simultaneous multiple view for probes reading, N.O./N.C. levels selection, inhibitor proportional dosing to WM1, WM2 or both, “biocide 2” proportional dosing to water meter, programmable biocide feed (max 1 per day), selection stop/no alarms for high/low feeding, working mode auto/manual/stop, permanent data storage with system log, stand-by input, mA output (optional), different working modes (on/off, impulsive proportional, proportional PWM and fixed PWM), pre-bleed (educed water system conductivity before biocide dosing), blow down (discharge control on conductivity values), lockout (discharge valve locked for a settable time, after biocide dosage), timeout (maximum discharge valve opening time), programmable delay at dosing start-up (up to 99 minutes), PT100 temperature compensation, alarms and log report (hourly, daily, weekly, monthly).
MEASUREMENT PARAMETERS
pH ORP Chlorine Conductivity Temperature
WORKING MODE
- ON/OFF
- IMPULSIVE PROPORTIONAL
- PID
- PROPORTIONAL PWM
- FIXED PWM
FEATURES
- REMOTE CONTROL ETHERNET or 2G/3G option configurations are remotely manageable through portal: www.ermes-server. com.
- SOFTWARE Instrument software in English language. French and german available upon request
- CUSTOMIZATIONS Instruments are customizable with client logo on frontal panel
- PERMANENT DATA STORAGE (WITHOUT BATTERY) with system log on display
- DISPLAY Multiple probe readings
- alarms and connection status can be viewed on display
- Stand-by input
- TEMPERATURE PROBE INPUT 1 PT100 temperature probe input
- LOG MENU LOG menu for enable/disable log on output.
- mA OUTPUT (option)
- MULTIPLE PROBE READINGS
- Pre-bleed: Reduced water system conductivity before biocide dosing
- Blow down: Discharge control on conductivity values
- Blow down: Discharge control on conductivity values
- Lockout: Discharge valve locked for a settable time (after biocide dosage)
- Timeout: Maximum discharge valve opening time
- Programmable delay at dosing start-up (up to 99 minutes)
- Priority setting
- Alarms: conductivity (high/low) – Bleed timeout (conductivity not reached after set time) – product level – flow – alarm ‘Concentration factor’.
- N.O./N.C. levels selection
- Inhibitor proportional dosing to WM1
- WM2 or both
- Biocide 2 – proportional dosing to water meter
- Programmable biocide feed: max 7 per day
- Selection: stop/no alarms for high/low feeding
- Working mode: auto/manual/stop
COMMUNICATION
- ERMES
- MODBUS
CONFIGURATION
BASIC
- RS485 output to link other EMEC instruments
WIFI
- RS485 output to link other EMEC instruments
- Web ERMES remote control (PC, smartphone or tablet)
- Alarm messages via email
ADVANCED USB
- RS485 output to link other EMEC instruments
- Data Log on USB device
ETHERNET
- RS485 output to link other EMEC instruments
- Web ERMES remote control (PC, smartphone or tablet)
- Alarm messages via email
2G – 3G
- RS485 output to link other EMEC instruments
- Web ERMES remote control (PC, smartphone or tablet)
- Alarm messages via email
- Alarm messages via SMS
MODBUS
- Connection to other PLC instruments via RS485 or TCP/IP for reading and modifying parameters