LOTUS AIR WITH PROBE MEASURE
CHLORINE DIOXIDE GENERATOR
LOTUS AIR with probe measure system produces, doses and controls chlorine dioxide for water disinfection. It is a pressure-less chlorine dioxide generator useful for those applications in which multi-point injection is required and it is equipped with a ClO2 probe (ECL2 or ECL17) or a mV probe (ERH), a probe holder and a filter.
Chlorine Dioxide is produced from diluted base chemicals: acid-chlorite process by hydrochloric acid (HCl 9%) and sodium chlorite (NaClO2 7,5%). Chlorine dioxide produced by LOTUS AIR with probe measure is stocked into a tank and then dosed proportionally to the request.
Dosing is multi-point and proportional to the volumetric flow rate. Chlorine dioxide is produced in a BATCH process. The reaction process takes place at ATMOSPHERIC PRESSURE. An active carbon filter prevents potential exhalations.
LOTUS AIR with probe measure is designed so that the reaction to produce chlorine dioxide takes place in a reaction chamber. A multifunction valve guarantees the safety of process.
GAS sensor option
LOTUS AIR with probe measure equipped with gas sensor detection.
FEATURES
- Stand-by input
- Multi-point proportional dosing
- Alarms: products – water – emptying
- Water meter input
- Real time production data
- ClO2 probe reading (LOTUS AIR ECL2 – LOTUS AIR ECL17)
- Temperature probe reading (probe and accessories not included)
- mV probe reading (LOTUS AIR ERH)
- Pumps and SEFL flow sensors monitoring
- Service due data
- LOTUS AIR control instrument
- ERMES communication
- ClO2 concentration measure
- PVDF ball valve for reaction chamber empty
- ClO2 concentration: 2 gr/l
- 3 metering pumps: red HCl pump – blue NaCLO2 pump – grey ClO2 pump
- Multifunction valve (MFKT/V)
- Double chamber: reaction and storage
- ASA (Acrylonitrile Styrene Acrylate) or fiberglass (Lotus Air 30/60 models) enclosure
- IP65 protection (NEMA4x) of LOTUS control instrument
- ENCODER wheel control
- Working temperature: 0-45°C (32-110°F)
MODELS
LOTUS AIR 10 WITH PROBE MEASURE
HOUR CAPACITY : 10 g/h
PRESSURE :3 bar
CHEMICAL CONSUMPTION
- HCl 0.25 l/h
- NaClO2 0.25 l/h
CONCENTRATION : 2 g/l
LOTUS AIR 30 WITH PROBE MEASURE
HOUR CAPACITY : 30 g/h
PRESSURE : 3 bar
CHEMICAL CONSUMPTION
- HCl 0.75 l/h
- NaClO2 0.75 l/h
CONCENTRATION : 2 g/l
LOTUS AIR 60 WITH PROBE MEASURE
HOUR CAPACITY : 60 g/h
PRESSURE : 5 bar
CHEMICAL CONSUMPTION
- HCl 1.5 l/h
- NaClO2 1.5 l/h
CONCENTRATION : 2 g/l
COMMUNICATION
- ERMES
- MODBUS
CONFIGURATION

BASIC
- RS485 output to link other EMEC instruments

WIFI
- RS485 output to link other EMEC instruments
- Web ERMES remote control (PC, smartphone or tablet)
- Alarm messages via email

ADVANCED USB
- RS485 output to link other EMEC instruments
- Data Log on USB device

ETHERNET
- RS485 output to link other EMEC instruments
- Web ERMES remote control (PC, smartphone or tablet)
- Alarm messages via email

2G – 3G
- RS485 output to link other EMEC instruments
- Web ERMES remote control (PC, smartphone or tablet)
- Alarm messages via email
- Alarm messages via SMS

MODBUS
- Connection to other PLC instruments via RS485 or TCP/IP for reading and modifying parameters
CERTIFICATE

Quality Austria | www.qualityaustria.com

IQNet Association | www.imq.it