About EC24

EC24 is a GfG gas transmitter that uses an electrochemical sensor to measure toxic gases, hydrogen (H2) and oxygen (O2). The unit is certified ATEX II 3G Ex nR ic IIC T6 X Gc and is safe to install in Zone 2 hazardous areas. Aluminum housing rated IP66, stainless steel sensor head rated IP52. Analog 0.2-1 mA or 4-20 mA signal transmission to the GMA controller. Measuring range and gas type depend on the sensor, from a few ppm to 2000 ppm for toxic gases and 0-25% by volume for O2.

Key features

  • ATEX II 3G Ex nR ic IIC T6 X Gc certification for Zone 2 hazardous areas
  • Electrochemical sensor for toxic gases, hydrogen (H2) and oxygen (O2)
  • IP66 aluminum housing, IP52 stainless steel sensor head
  • Analog 0.2-1 mA or 4-20 mA signal to the GMA controller
  • Measures many gases: Cl2, CO, H2S, NH3, NO2, SO2, O3, HCl, HCN, HF, H2, O2... depending on sensor
Specifications

Technical data

Operating principleElectrochemical
Gases detectedCl2, CO, H2S, NH3, NO2, SO2, O3, HCl, HCN, HF, H2, O2 (depending on sensor)
Measuring rangeA few ppm to 2000 ppm (toxic gases); O2 0-25% by volume
OutputsAnalog 0.2-1 mA or 4-20 mA
Power supply10 to 26 V DC
Enclosure / protectionAluminum IP66; stainless steel sensor head IP52
CertificationsATEX II 3G Ex nR ic IIC T6 X Gc (Zone 2)
Dimensions / weight80 x 125 x 60 mm; 980 g