GFG · Germany · Fixed systems
CS22
GFG CS22 gas transmitter (chemisorption)
Chemisorption transmitter for toxic gases, combustible gases and refrigerants, CS22 D version with display
Need the datasheet? Email info@vietthaiaqua.com
Description
About CS22
CS22 is a GFG 22 series transmitter that uses the chemisorption principle to measure toxic gases, combustible gases and many refrigerants outside hazardous areas. Measuring ranges include 0-100% LEL, 0-5000 ppm and 0-1% by volume, suited to uses from laboratories to industrial refrigeration systems. Analog 0.2-1 mA / 4-20 mA or digital RS485 (Modbus) signal transmission. The CS22 D version has a 2.2 inch color display and a local alarm buzzer; the display background turns red on alarm.
Key features
- Chemisorption principle
- Measuring range 0-100% LEL, 0-5000 ppm or 0-1% by volume
- Measures NH3, CH4 and many refrigerants (R-134a, R-410A, R-717...)
- Analog 0.2-1 mA / 4-20 mA or digital RS485 signal
- CS22 D version with 2.2 inch display and alarm buzzer
Specifications
Technical data
| Operating principle | Chemisorption |
|---|---|
| Measuring range | 0-100% LEL / 0-5000 ppm / 0-1% by volume |
| Response time | t90 under 15 seconds |
| Outputs | Analog 0.2-1 mA / 4-20 mA or digital RS485 |
| Temperature | -20 to +50°C |
| Power supply | 12 to 30 V DC |
| Enclosure / protection | Plastic, IP54 |
| Dimensions | 96 x 140 x 49 mm (W x H x D) |